On the influence of manufacturing inaccuracies of the structural elements of a piezoelectric transducer on the duration of an acoustic probing pulse
https://doi.org/10.21869/2223-1536-2025-15-2-58-73
Abstract
The purpose of the research is to determine determine the duration of acoustic signals emitted by a piezoelectric transducer with small deviations (increase or decrease) in the thickness of the matching layer and its specific acoustic resistance from the optimal values.
Methods. The object of the study is plate-type piezoelectric transducers loaded onto an water medium. The calculation was performed using the equivalent circuit method of piezoelectric transducers and the spectral method based on Fourier transforms. The equivalent circuit method is used to determine the frequency characteristics of piezoelectric transducers. For an electrical excitation pulse of a specific shape, its spectral function is determined using the direct Fourier transform. The type of the probing acoustic pulse is found using the inverse Fourier transform. Based on the analysis of the pulsed operating mode of piezoelectric transducers, the dependences of the probing signal durations on the optimal values of the wave thickness of the matching layer and its specific acoustic resistance are determined.
Results. Based on the analysis of the operation of piezoelectric transducers, the main causes of violation of the identity of their properties are identified. For different degrees of damping of the piezoelectric transducer, the shapes of the probing signals radiated into water are determined. The effect of inaccuracies in the manufacture of the layer on the duration of the probing signal is assessed. The duration of acoustic signals emitted by a piezoelectric transducer is determined with small deviations (increase or decrease) in the thickness of the matching layer and its specific acoustic resistance from the optimal values.
Conclusion. The obtained results are intended to assess the quality of blanks of structural elements of piezoelectric transducers during their manufacture in small batches, when errors in maintaining the thickness of the matching layer and the value of its specific acoustic resistance are inevitable both within one batch and between batches.
About the Authors
S. I. KonovalovRussian Federation
Sergey I. Konovalov, Doctor of Sciences (Engineering), Professor
5/F Professora Popova Str., St. Petersburg 197022
M. S. Vechera
Russian Federation
Mikhail S. Vechera, Post-Graduate Student
5/F Professora Popova Str., St. Petersburg 197022
R. S. Konovalov
Russian Federation
Roman S. Konovalov, Candidate of Sciences (Engineering), Associate Professor, Head of the Department of Electroacoustics and Ultrasound Technology; Associate Professor
5/F Professora Popova Str., St. Petersburg 197022
9 Moskovsky Ave., St. Petersburg 190031
V. M. Tsaplev
Russian Federation
Valery M. Tsaplev, Doctor of Sciences (Engineering), Professor
5/F Professora Popova Str., St. Petersburg 197022
Z. M. Yuldashev
Russian Federation
Zafar M. Yuldashev, Doctor of Sciences (Engineering), Professor, Head of the Department of Biotechnical Systems
5/F Professora Popova Str., St. Petersburg 197022
References
1. Uchino K. Piezoelectric Devices for Sustainability Technologies. Encyclopedia of Sustainable Technologies (Second Edition). 2024;3:463–477. https://doi.org/10.1016/ B978-0-323-90386-8.00014-0
2. Memon A., Alhems L. EMAT Generated Guided Waves in Pipes: A Review. e-Journal of Nondestructive Testing. 2023;28(10). https://doi.org/10.58286/28711
3. Lian Y., Du F., Xie L., Hu Q., Jin P., Wang Y., Lu Z. Application of Laser Ultrasonic Testing Technology in The Characterization of Material Properties: A Review. Measurement. 2024;234:114855. https://doi.org/10.1016/j.measurement.2024.114855Get rights and content
4. Sabri Salim M., Malek M. F. A., Heng R. B. W., Juni K. M., Sabri N. Capacitive Micromachined Ultrasonic Transducers: Technology and Application. Journal of Medical Ultrasound. 2012;20(1):8–31. https://doi.org/10.1016/j.jmu.2012.02.001
5. Ali Mangi M., Elahi H., Ali A., Jabbar H., Aqeel Bin A., Farrukh A., Bibi S., Altabey W. A., Kouritem S. A., Noori M. Applications of Piezoelectric-Based Sensors, Actuators, and Energy Harvesters. Sensors and Actuators Reports. 2025;9:100302. https://doi.org/10.1016/j.snr.2025.100302
6. Zhou Q., Ho Lam K., Zheng H., Qiu W., Kirk K. Shung. Piezoelectric Single Crystal Ultrasonic Transducers for Biomedical Applications. Progress in Materials Science. 2014;66:87–111. https://doi.org/10.1016/j.pmatsci.2014.06.001
7. Zhou Q., Lau S., Wu D., Shung K. Kirk. Piezoelectric Films for High Frequency Ultrasonic Transducers in Biomedical Applications. Progress in Materials Science. 2011;56(2):139–174. https://doi.org/10.1016/j.pmatsci.2010.09.001
8. Stepanov B.G. Piezoelectric transducers of rod and plate types with amplitude-phase excitation. Problems of synthesis and analysis. Saint Petersburg: Izdatel’stvo SPbGETU "LETI"; 2019. 220 p. (In Russ.)
9. Konovalov S.I., Kuz’menko A.G. Physical foundations of operation and design of pulse piezoelectric transducers in measurement and control problems. Saint Petersburg: Izdatel’stvo SPbGETU "LETI"; 2016. 228 p. (In Russ.)
10. Dou P., Jia Y., Zheng P., Wu T., Yu M., Reddyhoff T., Peng Z. Review of Ultrasonic-Based Technology for Oil Film Thickness Measurement in Lubrication. Tribology International. 2022;165:107290. https://doi.org/10.1016/j.triboint.2021.107290
11. Janů P.P., Bajer J., Dyčka P., Bystřický R. Precise experimental determination of electrical equivalent circuit parameters for ultrasonic piezoelectric ceramic transducers from their measured characteristics. Ultrasonics. 2021;112:106341. https://doi.org/10.1016/j.ultras.2020.106341
12. Liu W., Li D., Xie W. A Novel Time-of-Flight Difference Determination Method for Ultrasonic Thickness Measurement With Ultrasonic Echo Onset Point Detection. Applied Acoustics. 2025;233:110605. https://doi.org/10.1016/j.apacoust.2025.110605
13. Eason T.J., Bond L.J., Lozev M.G. Structural health monitoring ultrasonic thickness measurement accuracy and reliability of various time-of-flight calculation methods. In: 42nd Annual Review of Progress in Quantitative Nondestructive Evaluation: Incorporating the 6th European-American Workshop on Reliability. Vol. 1706. Minneapolis; 2016. Р. 200003. 2016;1706:200003. https://doi.org/10.1063/1.4940647
14. Jia L., Xue B., Chen S., Wu H., Yang X., Zhai J., Zeng Z. A High-Resolution Ultrasonic Ranging System Using Laser Sensing and a Cross-Correlation Method. Applied Sciences. 2019;(9):1483. https://doi.org/10.3390/app9071483
15. Oya J. R. G., Fort E. H., Miguel D. N., Rojas A. S., Carvajal R. G., Chavero F. M. Cross Correlation-Based Ultrasonic Gas Flow Sensor With Temperature Compensation. IEEE Transactions on Instrumentation and Measurement. 2023;72:1–4. https://doi.org/10.1109/TIM.2023.3293139
16. Wang D., Wang Z., Li P., Chen Y., Li H. Dual Gaussian attenuation model of ultrasonic echo and its parameter estimation. AIP Advances. 2019;(9):055213. https://doi.org/10.1063/1.5095994
17. Chang M., Lu Z., Huang Q., Yang C. Parameter estimation for ultrasonic echo signals through improved matching pursuit and flower pollination algorithms. Measurement. 2022;194:111010. https://doi.org/10.1016/j.measurement.2022.111010
18. Xiong J., Mao P., Li X. Enhancing Ultrasonic Time-of-Flight Estimation Using Adaptive Differential Evolution and Levenberg–Marquardt Algorithm. IEEE Sensors Journal. 2024;24(2):1224–1232. https://doi.org/10.1109/JSEN.2023.3324502
19. Ermolov I.N. (ed.). Ultrasonic Piezoelectric Transducers for Nondestructive Testing. Moscow: Mashinostroenie; 1986. 280 p. (In Russ.)
20. Konovalov S.I., Yuldashev Z.M. Formation of Probing Signals of Piezoelectric Transducers for Ultrasonic Testing. Izvestiya vuzov Rossii. Radioelektronika = Journal of the Russian Universities. Radioelectronics. 2023;26(1):87–98. (In Russ.) https://doi.org/10.32603/1993-8985-2023-26-1-87-98
Review
For citations:
Konovalov S.I., Vechera M.S., Konovalov R.S., Tsaplev V.M., Yuldashev Z.M. On the influence of manufacturing inaccuracies of the structural elements of a piezoelectric transducer on the duration of an acoustic probing pulse. Proceedings of the Southwest State University. Series: IT Management, Computer Science, Computer Engineering. Medical Equipment Engineering. 2025;15(2):58-73. (In Russ.) https://doi.org/10.21869/2223-1536-2025-15-2-58-73